ISO-CHEK® Technical Specifications & Methods Comparison
Frame Separator
 
COMPARISON OF OTHER METHODS vs ISO-CHEK®
Collection Technique  ISO-CHEK®
 
Dual Filter
Cassette
OSHA 42 5
Single Filter
Cassette
NIOSH 5521 6
Impinger
 
Monomer Oligomer Separation Yes No No
HDI, TDI Monomer Free From  Matrix Interference Yes No No
Derivatizing Reagent MAMA7 1-2PP8 1-2MPP9
Stable Reagent (Room Temp) Yes No 1O No 11
Handling Precautions None Refrig Refrig
Method of Analysis RP HPLC
w/UV, Fluor
RP HPLC
w/UV,Fluor
RP HPLC
w/UV,ECD
Sample Collection Time (minutes) 15 60 15-240
Sample Prep & Analysis Time (minutes) 45 75 75
Quantitation Limit12 (10 sigma2)
2,6-TDI
2,4-TDI
1,6-HDI
MDI

1.0
1.0
1.0
1.0/0.27

2.3
2.5
2.9
NA

0.5
0.7
1.0
0.3
Limit of Detection 13 (3 sigma2)
2,6-TDI
2,4-TDI
1,6-HDI
MDI

0.2
0.2
0.6
0.3/0.08

1.6
1.3
2.3
NA

0.1
0.1
0.1
0.1
Precision of Analysis (CV)  0.02  0.009 Unknown 14
Range Tested for Precision (mg/m3) 1-280 70-280 NA 15
Reproducibility/Accuracy16
% Recovery
SD

100.3-100.6
1- 1.6

100.5-105.4
1.6-2.4

Not
Determined

- FOOTNOTES -

5 OSHA Method 42 for the analysis of diisocyanates
6,11,14,15 NIOSH Method 5521, Monomeric Isocyanates
7 9-(N-methylaminomethyl)anthracene
8 1-(2-pyridylpiperazine)
9 1-(2-Methoxypyridylpiperazine)
10 Poster session, 1996 AIHCE, Paper #398; Meyer, P. and Czarnecki, M.
12,13 Detection limits for ISO-CHEK® and method 42 are µg/m3 in 15 liter sample. For method 5521, limits are stated as "per sample" with sample volume range given as 5-500L, and limits were established using pure standards without derivatizing reagent. For MDI, the first number of the pair for ISO-CHEK TM is with a UV detector, the second with a fluorescence detector.
16 Recovery of spiked standards by analysis not associated with method
NA Data not available or determined

Knowledge Base Article # 204
ISO-CHEK® Technical Specifications & Methods Comparison

Frame Separator
Home Frame Separator Products Frame Separator Literature Frame Separator Support Frame Separator News Frame Separator Corporate Frame Separator Distributors Frame Separator Site Map
Frame Separator

©SKC Omega Specialty Division, 2010, All Rights Reserved
A Subsidiary of SKC Gulf Coast Inc.
9827 Whithorn Drive, Houston, TX USA 77095
Phone: 1-281-859-3418    Fax: 1-281-859-1303